Infrastructure - Cisco UCS Opspack
The Cisco Unified Computing System (UCS) is a data center server computer product line composed of computing hardware, virtualization support, switching fabric, and management software.
What You Can Monitor
This Opspack will monitor various aspects of UCS such as the top level Fabric, Chassis, Blades and Racks.
Host Templates
The following Host Templates are currently provided by this Opspack. Click the name of each Host Template to be taken to the relevant information page, including a full Service Check description and usage instructions.
Cisco UCS - Blade
add_circleService Check Name | Description | Default Thresholds (Warning, Critical) | UOM |
---|---|---|---|
UCS - Blade - Adaptors | Information on the adaptors connected to this Blade | N/A | N/A |
UCS - Blade - Admin Power | Admin power of the Blade | N/A | N/A |
UCS - Blade - Admin State | Admin State of the Blade | N/A | N/A |
UCS - Blade - Association State | Association State of the Blade | N/A | N/A |
UCS - Blade - Availability | Availability of the Blade | N/A | N/A |
UCS - Blade - Boards | Information on the Boards connected to this Blade | N/A | N/A |
UCS - Blade - Board Controllers | Information on the Board Controllers connected to this Blade | N/A | N/A |
UCS - Blade - Checkpoint | Latest checkpoint of the Blade | N/A | N/A |
UCS - Blade - Connection Path | Connection Path of the Blade | N/A | N/A |
UCS - Blade - Connection State | Connection State of the Blade | N/A | N/A |
UCS - Blade - Discovery State | Discovery State of the Blade | N/A | N/A |
UCS - Blade - Faults | Fault information for the Blade Server | blade_critical_faults=,0 blade_major_faults=,0 blade_minor_faults=0, blade_warning_faults=0, blade_info_faults=, blade_cleared_faults=, |
N/A |
UCS - Blade - HBAs | Number of HBAs for the Blade | N/A | N/A |
UCS - Blade - Local Storage Health | Health information for the Local Storage on this Blade | N/A | N/A |
UCS - Blade - Local Storage Usage | Usage information for the Local Storage on this Blade | N/A | N/A |
UCS - Blade - Managing Instance | Managing Instance of the Blade | N/A | N/A |
UCS - Blade - Memory Unit Health | Information on the Memory Units connected to this Blade | N/A | N/A |
UCS - Blade - Memory Usage | Memory usage of the Blade | memory_usage=70,90 | N/A |
UCS - Blade - NICs | Number of NICs for the Blade | N/A | N/A |
UCS - Blade - Operability | Operability of the Blade | N/A | N/A |
UCS - Blade - Operational State | Operational State of the Blade | N/A | N/A |
UCS - Blade - Operational State Qualifier | Operational State Qualifier of the Blade | N/A | N/A |
UCS - Blade - Power State | Power State of the Blade | N/A | N/A |
UCS - Blade - Presence | Presence of the Blade | N/A | N/A |
UCS - Blade - Processor Health | Information on the Processors connected to this Blade | N/A | N/A |
UCS - Blade - Processor Usage | Processor usage of the Blade | cpu_usage=, cores_enabled=,1: |
N/A |
UCS - Blade - Revision | Revision number of the Blade | N/A | N/A |
UCS - Blade - Service Profile | Service Profile of the Blade | N/A | N/A |
UCS - Blade - Threads | Number of Threads of the Blade | N/A | N/A |
Cisco UCS - Chassis
add_circleService Check Name | Description | Default Thresholds (Warning, Critical) | UOM |
---|---|---|---|
UCS - Chassis - Admin State | Admin state of the Chassis | N/A | N/A |
UCS - Chassis - Availability | Availability of the Chassis | N/A | N/A |
UCS - Chassis - Blades | Information on the Blade Servers connected to this Chassis | N/A | N/A |
UCS - Chassis - Config State | Config state of the Chassis | N/A | N/A |
UCS - Chassis - Connection Path | Connection path of the Chassis | N/A | N/A |
UCS - Chassis - Connection State | Connection state of the Chassis | N/A | N/A |
UCS - Chassis - Faults | Fault information for the Chassis | chassis_critical_faults=,0 chassis_major_faults=,0 chassis_minor_faults=0, chassis_warning_faults=0, chassis_info_faults=, chassis_cleared_faults=, |
N/A |
UCS - Chassis - IO Cards | Information on the IO Cards on this Chassis | N/A | N/A |
UCS - Chassis - Managing Instance | Managing Instance of the Chassis | N/A | N/A |
UCS - Chassis - Operability | Operability of the Chassis | N/A | N/A |
UCS - Chassis - Overall State | Overall state of the Chassis | N/A | N/A |
UCS - Chassis - Power State | Power state of the Chassis | N/A | N/A |
UCS - Chassis - Presence | Presence of the Chassis | N/A | N/A |
UCS - Chassis - PSUs | PSU stats for the Chassis | N/A | N/A |
UCS - Chassis - Redundancy Qualifier | Redundancy qualifier of the Chassis | N/A | N/A |
UCS - Chassis - Redundancy State | Redundancy state of the Chassis | N/A | N/A |
UCS - Chassis - Revision | Revision number of the Chassis | N/A | N/A |
UCS - Chassis - Thermal State | Thermal state of the Chassis | N/A | N/A |
Cisco UCS - Custom
add_circleService Check Name | Description | Default Thresholds (Warning, Critical) | UOM |
---|---|---|---|
UCS - Custom - Query | User-defined query against an object in the UCS component hierarchy | N/A | N/A |
Cisco UCS - Fabric
add_circleService Check Name | Description | Default Thresholds (Warning, Critical) | UOM |
---|---|---|---|
UCS - Fabric - Extenders | Information about the Fabric Extenders that are part of this Fabric | N/A | N/A |
UCS - Fabric - Extender Faults | Information about the Faults on this Fabric Extender | N/A | N/A |
UCS - Fabric - Interconnects | Information about the Fabric Interconnects that are part of this Fabric | N/A | N/A |
UCS - Fabric - Interconnect Faults | Information about the Faults on this Fabric Interconnect | N/A | N/A |
Cisco UCS - Rack
add_circleService Check Name | Description | Default Thresholds (Warning, Critical) | UOM |
---|---|---|---|
UCS - Rack - Admin Power | Admin power for the Rack | N/A | N/A |
UCS - Rack - Admin State | Admin state for the Rack | N/A | N/A |
UCS - Rack - Association State | Association state of the Rack | N/A | N/A |
UCS - Rack - Availability | Availability of the Rack | N/A | N/A |
UCS - Rack - Boards | Information on the boards on the Rack | N/A | N/A |
UCS - Rack - Board Controllers | Information on the board controllers on the Rack | N/A | N/A |
UCS - Rack - Checkpoint | Latest checkpoint of the Rack | N/A | N/A |
UCS - Rack - Connection Path | Connection path of the Rack | N/A | N/A |
UCS - Rack - Connection State | Connection state of the Rack | N/A | N/A |
UCS - Rack - Discovery State | Discovery state of the Rack | N/A | N/A |
UCS - Rack - Faults | Fault information for the Rack server | rack_critical_faults=,0 rack_major_faults=,0 rack_minor_faults=0, rack_warning_faults=0, rack_info_faults=, rack_cleared_faults=, |
N/A |
UCS - Rack - HBAs | Number of HBAs for the Rack | N/A | N/A |
UCS - Rack - Local Storage Health | Health information for the Local Storage on the Rack | N/A | N/A |
UCS - Rack - Local Storage Usage | Usage information for the local storage on the Rack | N/A | N/A |
UCS - Rack - Managing Instance | Managing instance of the Rack | N/A | N/A |
UCS - Rack - Memory Unit Health | Information on the memory units on the Rack | N/A | N/A |
UCS - Rack - Memory Usage | Memory usage of the Rack | memory_usage=70,90 | N/A |
UCS - Rack - NICs | Number of NICs for the Rack | N/A | N/A |
UCS - Rack - Operability | Operability of the Rack | N/A | N/A |
UCS - Rack - Operational State | Operational State of the Rack | N/A | N/A |
UCS - Rack - Operational State Qualifier | Operational State Qualifier of the Rack | N/A | N/A |
UCS - Rack - Power State | Power state of the Rack | N/A | N/A |
UCS - Rack - Presence | Presence of the Rack | N/A | N/A |
UCS - Rack - Processor Health | Information on the processors on the Rack | N/A | N/A |
UCS - Rack - Processor Usage | Processor usage of the Rack | cpu_usage=, cores_enabled=,1: |
N/A |
UCS - Rack - PSUs | Information on the PSUs on the Rack | N/A | N/A |
UCS - Rack - Service Profile | Service profile associated with the Rack | N/A | N/A |
UCS - Rack - Threads | Number of threads on the Rack | N/A | N/A |
Prerequisites
Setup For Monitoring
- This Opspack requires either UCS Manager or CIMC Supervisor. The API server URL will be the IP address of either the UCS Manager or the CIMC Supervisor starting with https://
- Each Host Template requires the name of the object being monitored. This can be retrieved from the Distinguised Name (DN) of the object. For example, to monitor a chassis with DN 'sys/chassis-1', enter 'chassis-1' as the Chassis Name.
- Opsview will require a read-only user on your UCS system.